{"id":75589,"date":"2026-06-18T10:31:59","date_gmt":"2026-06-18T08:31:59","guid":{"rendered":"https:\/\/www.refsas.com\/heizelement-ihres-dentalofens-defekt-finden-sie-schnell-den-passenden-ersatz\/"},"modified":"2026-06-18T12:04:52","modified_gmt":"2026-06-18T10:04:52","slug":"heizelement-ihres-dentalofens-defekt-finden-sie-schnell-den-passenden-ersatz","status":"publish","type":"page","link":"https:\/\/www.refsas.com\/de\/heizelement-ihres-dentalofens-defekt-finden-sie-schnell-den-passenden-ersatz\/","title":{"rendered":"Heizelement Ihres Dentalofens defekt? Finden Sie schnell den passenden Ersatz."},"content":{"rendered":"<div class=\"wpb-content-wrapper\"><p>[vc_row row_height_percent=&#8220;50&#8243; back_color=&#8220;color-wayh&#8220; back_image=&#8220;74962&#8243; overlay_color=&#8220;color-wayh&#8220; overlay_alpha=&#8220;50&#8243; gutter_size=&#8220;3&#8243; column_width_percent=&#8220;100&#8243; shift_y=&#8220;0&#8243; z_index=&#8220;0&#8243; content_parallax=&#8220;0&#8243; uncode_shortcode_id=&#8220;561251&#8243; back_color_type=&#8220;uncode-palette&#8220; overlay_color_type=&#8220;uncode-palette&#8220;][vc_column column_width_percent=&#8220;100&#8243; gutter_size=&#8220;3&#8243; overlay_alpha=&#8220;50&#8243; shift_x=&#8220;0&#8243; shift_y=&#8220;0&#8243; shift_y_down=&#8220;0&#8243; z_index=&#8220;0&#8243; medium_width=&#8220;0&#8243; mobile_width=&#8220;0&#8243; width=&#8220;1\/1&#8243; mobile_height=&#8220;340&#8243;][\/vc_column][\/vc_row][vc_row row_height_percent=&#8220;0&#8243; override_padding=&#8220;yes&#8220; h_padding=&#8220;2&#8243; top_padding=&#8220;2&#8243; bottom_padding=&#8220;2&#8243; overlay_alpha=&#8220;50&#8243; gutter_size=&#8220;3&#8243; column_width_percent=&#8220;100&#8243; shift_y=&#8220;0&#8243; z_index=&#8220;0&#8243; content_parallax=&#8220;0&#8243; uncode_shortcode_id=&#8220;185793&#8243;][vc_column column_width_percent=&#8220;100&#8243; gutter_size=&#8220;3&#8243; override_padding=&#8220;yes&#8220; column_padding=&#8220;3&#8243; back_color=&#8220;color-xsdn&#8220; overlay_alpha=&#8220;50&#8243; shift_x=&#8220;0&#8243; shift_y=&#8220;-5&#8243; shift_y_fixed=&#8220;yes&#8220; shift_y_down=&#8220;0&#8243; z_index=&#8220;0&#8243; medium_width=&#8220;0&#8243; mobile_width=&#8220;0&#8243; width=&#8220;1\/1&#8243;][vc_row_inner row_inner_height_percent=&#8220;0&#8243; overlay_alpha=&#8220;50&#8243; equal_height=&#8220;yes&#8220; gutter_size=&#8220;0&#8243; shift_y=&#8220;0&#8243;][vc_column_inner column_width_percent=&#8220;100&#8243; position_vertical=&#8220;middle&#8220; align_horizontal=&#8220;align_right&#8220; gutter_size=&#8220;3&#8243; override_padding=&#8220;yes&#8220; column_padding=&#8220;2&#8243; overlay_alpha=&#8220;50&#8243; border_color=&#8220;color-gyho&#8220; border_style=&#8220;solid&#8220; shift_x=&#8220;0&#8243; shift_y=&#8220;0&#8243; shift_y_down=&#8220;0&#8243; z_index=&#8220;0&#8243; medium_width=&#8220;2&#8243; align_mobile=&#8220;align_center_mobile&#8220; mobile_width=&#8220;0&#8243; width=&#8220;3\/12&#8243; css=&#8220;.vc_custom_1550588745751{border-right-width: 1px !important;padding-top: 0px !important;padding-bottom: 0px !important;}&#8220;][vc_single_image media=&#8220;73247&#8243; media_width_percent=&#8220;20&#8243; alignment=&#8220;center&#8220; advanced=&#8220;yes&#8220; media_overlay_opacity=&#8220;50&#8243; media_overlay_anim=&#8220;no&#8220; media_text_anim=&#8220;no&#8220; media_padding=&#8220;0&#8243;][\/vc_column_inner][vc_column_inner column_width_percent=&#8220;100&#8243; position_vertical=&#8220;middle&#8220; gutter_size=&#8220;3&#8243; override_padding=&#8220;yes&#8220; column_padding=&#8220;2&#8243; overlay_alpha=&#8220;50&#8243; shift_x=&#8220;0&#8243; shift_y=&#8220;0&#8243; shift_y_down=&#8220;0&#8243; z_index=&#8220;0&#8243; medium_width=&#8220;6&#8243; align_mobile=&#8220;align_center_mobile&#8220; mobile_width=&#8220;0&#8243; width=&#8220;9\/12&#8243;][vc_custom_heading heading_semantic=&#8220;h1&#8243; text_weight=&#8220;200&#8243; text_italic=&#8220;yes&#8220; uncode_shortcode_id=&#8220;125167&#8243;]Heizelement Ihres Dentalofens defekt? Finden Sie schnell den passenden Ersatz.[\/vc_custom_heading][\/vc_column_inner][\/vc_row_inner][\/vc_column][\/vc_row][vc_row row_height_percent=&#8220;0&#8243; overlay_alpha=&#8220;50&#8243; gutter_size=&#8220;3&#8243; column_width_percent=&#8220;100&#8243; shift_y=&#8220;0&#8243; z_index=&#8220;0&#8243; content_parallax=&#8220;0&#8243; uncode_shortcode_id=&#8220;146347&#8243;][vc_column column_width_percent=&#8220;100&#8243; gutter_size=&#8220;3&#8243; overlay_alpha=&#8220;50&#8243; shift_x=&#8220;0&#8243; shift_y=&#8220;0&#8243; shift_y_down=&#8220;0&#8243; z_index=&#8220;0&#8243; medium_width=&#8220;0&#8243; mobile_width=&#8220;0&#8243; width=&#8220;1\/1&#8243; uncode_shortcode_id=&#8220;131105&#8243;][vc_column_text text_lead=&#8220;yes&#8220; uncode_shortcode_id=&#8220;103594&#8243;]SAS FOURS ist ein Industrieunternehmen, das auf \u00d6fen, feuerfeste Produkte und <a href=\"https:\/\/www.refsas.com\/de\/heizelemente-fur-die-industrie\/\">Heizelemente<\/a> wie MoSi\u2082 und SiC spezialisiert ist: dieselben Technologien, die in zahlreichen <strong>Brenn\u00f6fen f\u00fcr Dentalkeramik<\/strong> verbaut sind.[\/vc_column_text][\/vc_column][\/vc_row][vc_row][vc_column column_width_percent=&#8220;100&#8243; gutter_size=&#8220;3&#8243; override_padding=&#8220;yes&#8220; column_padding=&#8220;3&#8243; overlay_color=&#8220;color-dfgh&#8220; overlay_alpha=&#8220;5&#8243; border_color=&#8220;color-dfgh&#8220; border_style=&#8220;solid&#8220; shift_x=&#8220;0&#8243; shift_y=&#8220;0&#8243; shift_y_down=&#8220;0&#8243; z_index=&#8220;0&#8243; medium_width=&#8220;0&#8243; mobile_width=&#8220;0&#8243; width=&#8220;1\/1&#8243; uncode_shortcode_id=&#8220;407347&#8243; overlay_color_type=&#8220;uncode-palette&#8220; css=&#8220;.vc_custom_1774622541109{border-left-width: 4px !important;}&#8220; border_color_type=&#8220;uncode-palette&#8220;][vc_column_text text_color=&#8220;color-wayh&#8220; uncode_shortcode_id=&#8220;621643&#8243; text_color_type=&#8220;uncode-palette&#8220;]<\/p>\n<h2>Ausfall im Dentallabor: Schnelles Handeln erforderlich<\/h2>\n<p>Ein defektes Heizelement setzt Ihren Ofen au\u00dfer Betrieb und kann Ihre prothetischen Arbeiten sofort blockieren. Senden Sie uns die Referenznummer, die Marke oder ein Foto des Elements: Wir identifizieren die kompatible L\u00f6sung und senden Ihnen ein <a href=\"https:\/\/www.refsas.com\/de\/kontakt\/\">Angebot innerhalb von 24 Std.<\/a>[\/vc_column_text][\/vc_column][\/vc_row][vc_row][vc_column column_width_percent=&#8220;100&#8243; position_vertical=&#8220;middle&#8220; align_horizontal=&#8220;align_center&#8220; gutter_size=&#8220;3&#8243; overlay_alpha=&#8220;50&#8243; shift_x=&#8220;0&#8243; shift_y=&#8220;0&#8243; shift_y_down=&#8220;0&#8243; z_index=&#8220;0&#8243; medium_width=&#8220;0&#8243; mobile_width=&#8220;0&#8243; width=&#8220;1\/1&#8243; uncode_shortcode_id=&#8220;200969&#8243;][vc_button button_color=&#8220;color-iopl&#8220; radius=&#8220;btn-round&#8220; border_width=&#8220;0&#8243; link=&#8220;url:https%3A%2F%2Fwww.refsas.com%2Ffour-dentaire-en-panne%2F|title:Angebot%20f%C3%BCr%20dringende%20Dentalofenreparatur|&#8220; uncode_shortcode_id=&#8220;195256&#8243; button_color_type=&#8220;uncode-palette&#8220;]Angebot f\u00fcr dringende Dentalofenreparatur[\/vc_button][\/vc_column][\/vc_row][vc_row][vc_column width=&#8220;1\/1&#8243;][vc_column_text uncode_shortcode_id=&#8220;185266&#8243;]<\/p>\n<h2>Was ist ein Heizelement f\u00fcr einen Dentallaborofen?<\/h2>\n<p>Ein Heizelement f\u00fcr einen Dentallaborofen ist eine Komponente, die in der Regel aus MoSi\u2082 (Molybd\u00e4ndisilizid) oder Siliziumkarbid (SiC) besteht und das Erreichen der hohen Temperaturen erm\u00f6glicht, die f\u00fcr das Brennen von Keramik oder das Sintern von Zirkonoxid erforderlich sind. Im Falle eines Defekts oder Bruchs ist der Austausch des Heizelements des Dentalofens unerl\u00e4sslich, um das Ger\u00e4t wieder in Betrieb zu nehmen. Diese Elemente sind f\u00fcr den Betrieb bei Temperaturen zwischen 900 \u00b0C und 1600 \u00b0C ausgelegt und bieten eine hohe thermische Stabilit\u00e4t sowie eine gro\u00dfe Heizpr\u00e4zision.  <\/p>\n<h2>Warum werden MoSi\u2082-Heizelemente in Dental\u00f6fen verwendet?<\/h2>\n<p>Der W\u00e4rmebedarf variiert je nach Typ des Dentalofens.<br \/>\nKeramikbrenn\u00f6fen arbeiten in der Regel bei niedrigeren Temperaturen, w\u00e4hrend Zirkonoxid-Sinter\u00f6fen \u00fcblicherweise Temperaturen zwischen 1.450 \u00b0C und 1.600 \u00b0C erreichen.<br \/>\nDieser extreme Temperaturbereich schlie\u00dft die meisten herk\u00f6mmlichen metallischen Heizelemente aus. Elemente aus Molybd\u00e4ndisilizid (MoSi\u2082) sind aus einem einfachen Grund zum Standard auf diesem Markt geworden: Sie sind f\u00fcr den Dauereinsatz bei sehr hohen Temperaturen mit exzellenter thermischer Stabilit\u00e4t konzipiert.[\/vc_column_text][\/vc_column][\/vc_row][vc_row row_height_percent=&#8220;0&#8243; back_color=&#8220;color-iopl&#8220; overlay_alpha=&#8220;50&#8243; gutter_size=&#8220;3&#8243; column_width_percent=&#8220;100&#8243; shift_y=&#8220;0&#8243; z_index=&#8220;0&#8243; content_parallax=&#8220;0&#8243; uncode_shortcode_id=&#8220;664662&#8243; back_color_type=&#8220;uncode-palette&#8220;][vc_column column_width_percent=&#8220;100&#8243; gutter_size=&#8220;3&#8243; overlay_alpha=&#8220;50&#8243; shift_x=&#8220;0&#8243; shift_y=&#8220;0&#8243; shift_y_down=&#8220;0&#8243; z_index=&#8220;0&#8243; medium_width=&#8220;0&#8243; mobile_width=&#8220;0&#8243; width=&#8220;1\/1&#8243; uncode_shortcode_id=&#8220;472717&#8243;][vc_row_inner row_inner_height_percent=&#8220;0&#8243; overlay_alpha=&#8220;100&#8243; gutter_size=&#8220;4&#8243; shift_y=&#8220;0&#8243;][vc_column_inner column_width_percent=&#8220;100&#8243; align_horizontal=&#8220;align_center&#8220; gutter_size=&#8220;3&#8243; style=&#8220;dark&#8220; overlay_alpha=&#8220;100&#8243; shift_x=&#8220;0&#8243; shift_y=&#8220;0&#8243; shift_y_down=&#8220;0&#8243; z_index=&#8220;0&#8243; medium_width=&#8220;3&#8243; mobile_width=&#8220;0&#8243; zoom_width=&#8220;0&#8243; zoom_height=&#8220;0&#8243; width=&#8220;1\/4&#8243; uncode_shortcode_id=&#8220;103214&#8243;][vc_icon icon=&#8220;fa fa-fire&#8220; icon_color=&#8220;color-xsdn&#8220; size=&#8220;fa-3x&#8220; heading_semantic=&#8220;p&#8220; text_size=&#8220;h5&#8243; text_weight=&#8220;400&#8243; text_reduced=&#8220;yes&#8220; align=&#8220;left&#8220; title=&#8220;Bis zu 1.800 \u00b0C&#8220; uncode_shortcode_id=&#8220;372550&#8243; icon_color_type=&#8220;uncode-palette&#8220;][\/vc_icon][\/vc_column_inner][vc_column_inner column_width_percent=&#8220;100&#8243; align_horizontal=&#8220;align_center&#8220; gutter_size=&#8220;3&#8243; style=&#8220;dark&#8220; overlay_alpha=&#8220;100&#8243; shift_x=&#8220;0&#8243; shift_y=&#8220;0&#8243; shift_y_down=&#8220;0&#8243; z_index=&#8220;0&#8243; medium_width=&#8220;3&#8243; mobile_width=&#8220;0&#8243; zoom_width=&#8220;0&#8243; zoom_height=&#8220;0&#8243; width=&#8220;1\/4&#8243; uncode_shortcode_id=&#8220;177838&#8243;][vc_icon icon=&#8220;fa fa-cogs&#8220; icon_color=&#8220;color-xsdn&#8220; size=&#8220;fa-3x&#8220; heading_semantic=&#8220;p&#8220; text_size=&#8220;h5&#8243; text_weight=&#8220;400&#8243; text_reduced=&#8220;yes&#8220; align=&#8220;left&#8220; title=&#8220;MoSi\u2082 \/ SiC Technologie&#8220; uncode_shortcode_id=&#8220;857103&#8243; icon_color_type=&#8220;uncode-palette&#8220;][\/vc_icon][\/vc_column_inner][vc_column_inner column_width_percent=&#8220;100&#8243; align_horizontal=&#8220;align_center&#8220; gutter_size=&#8220;3&#8243; style=&#8220;dark&#8220; overlay_alpha=&#8220;100&#8243; shift_x=&#8220;0&#8243; shift_y=&#8220;0&#8243; shift_y_down=&#8220;0&#8243; z_index=&#8220;0&#8243; medium_width=&#8220;3&#8243; mobile_width=&#8220;0&#8243; zoom_width=&#8220;0&#8243; zoom_height=&#8220;0&#8243; width=&#8220;1\/4&#8243; uncode_shortcode_id=&#8220;204141&#8243;][vc_icon icon=&#8220;fa fa-flag&#8220; icon_color=&#8220;color-xsdn&#8220; size=&#8220;fa-3x&#8220; heading_semantic=&#8220;p&#8220; text_size=&#8220;h5&#8243; text_weight=&#8220;400&#8243; text_reduced=&#8220;yes&#8220; align=&#8220;left&#8220; title=&#8220;Franz\u00f6sisches Industrieunternehmen seit 1934&#8243; uncode_shortcode_id=&#8220;187111&#8243; icon_color_type=&#8220;uncode-palette&#8220;][\/vc_icon][\/vc_column_inner][vc_column_inner column_width_percent=&#8220;100&#8243; align_horizontal=&#8220;align_center&#8220; gutter_size=&#8220;3&#8243; style=&#8220;dark&#8220; overlay_alpha=&#8220;50&#8243; shift_x=&#8220;0&#8243; shift_y=&#8220;0&#8243; shift_y_down=&#8220;0&#8243; z_index=&#8220;0&#8243; medium_visibility=&#8220;yes&#8220; medium_width=&#8220;3&#8243; mobile_width=&#8220;0&#8243; width=&#8220;1\/4&#8243; uncode_shortcode_id=&#8220;900621&#8243;][vc_icon icon=&#8220;fa fa-comments&#8220; icon_color=&#8220;color-xsdn&#8220; size=&#8220;fa-3x&#8220; heading_semantic=&#8220;p&#8220; text_size=&#8220;h5&#8243; text_weight=&#8220;400&#8243; text_reduced=&#8220;yes&#8220; align=&#8220;left&#8220; title=&#8220;Angebot innerhalb von 24 Stunden&#8220; uncode_shortcode_id=&#8220;160230&#8243; icon_color_type=&#8220;uncode-palette&#8220;][\/vc_icon][\/vc_column_inner][\/vc_row_inner][\/vc_column][\/vc_row][vc_row][vc_column width=&#8220;1\/1&#8243;][vc_column_text uncode_shortcode_id=&#8220;141722&#8243;]<\/p>\n<h2>Welches Heizelement passt zu Ihrem Dentalofen?<\/h2>\n<p>Es gibt zwei Hauptfamilien von Heizelementen, die in Dentallabor\u00f6fen verwendet werden. Die richtige Wahl h\u00e4ngt vom Ofenmodell, der Arbeitstemperatur und der internen mechanischen Konfiguration ab.[\/vc_column_text][vc_row_inner row_inner_height_percent=&#8220;0&#8243; overlay_alpha=&#8220;50&#8243; gutter_size=&#8220;3&#8243; shift_y=&#8220;0&#8243; z_index=&#8220;0&#8243; uncode_shortcode_id=&#8220;140398&#8243;][vc_column_inner column_width_percent=&#8220;100&#8243; gutter_size=&#8220;3&#8243; overlay_alpha=&#8220;50&#8243; shift_x=&#8220;0&#8243; shift_y=&#8220;0&#8243; shift_y_down=&#8220;0&#8243; z_index=&#8220;0&#8243; medium_width=&#8220;0&#8243; mobile_width=&#8220;0&#8243; width=&#8220;1\/1&#8243; uncode_shortcode_id=&#8220;110889&#8243;][\/vc_column_inner][\/vc_row_inner][vc_column_text uncode_shortcode_id=&#8220;518669&#8243;]<\/p>\n<h2>Kompatibilit\u00e4t mit den f\u00fchrenden Dentalofen-Marken<\/h2>\n<p>Keramikbrenn- und Sinter\u00f6fen, die in Dentallaboren eingesetzt werden (Ivoclar Vivadent, Vita, Dekema, Nabertherm, Mihm-Vogt oder andere Hersteller), sind in vielen F\u00e4llen mit MoSi\u2082- oder SiC-Elementen ausgestattet. Das Ersatzheizelement muss exakt den Abmessungen und der elektrischen Konfiguration des Originals entsprechen.[\/vc_column_text][vc_row_inner][vc_column_inner width=&#8220;1\/1&#8243;][\/vc_column_inner][\/vc_row_inner][\/vc_column][\/vc_row][vc_row row_height_percent=&#8220;0&#8243; overlay_alpha=&#8220;49&#8243; gutter_size=&#8220;3&#8243; column_width_percent=&#8220;100&#8243; shift_y=&#8220;0&#8243; z_index=&#8220;0&#8243; content_parallax=&#8220;0&#8243; uncode_shortcode_id=&#8220;802065&#8243;][vc_column column_width_percent=&#8220;100&#8243; gutter_size=&#8220;3&#8243; override_padding=&#8220;yes&#8220; column_padding=&#8220;3&#8243; overlay_color=&#8220;color-dfgh&#8220; overlay_alpha=&#8220;5&#8243; border_color=&#8220;color-dfgh&#8220; border_style=&#8220;solid&#8220; shift_x=&#8220;0&#8243; shift_y=&#8220;0&#8243; shift_y_down=&#8220;0&#8243; z_index=&#8220;0&#8243; medium_width=&#8220;0&#8243; mobile_width=&#8220;0&#8243; width=&#8220;1\/1&#8243; uncode_shortcode_id=&#8220;850585&#8243; overlay_color_type=&#8220;uncode-palette&#8220; css=&#8220;.vc_custom_1774622512779{border-left-width: 4px !important;}&#8220; border_color_type=&#8220;uncode-palette&#8220;][vc_column_text text_color=&#8220;color-wayh&#8220; uncode_shortcode_id=&#8220;211068&#8243; text_color_type=&#8220;uncode-palette&#8220;]<\/p>\n<h2>Sie kennen die genaue Referenznummer nicht?<\/h2>\n<p>Senden Sie uns die Marke, das Ofenmodell und wenn m\u00f6glich ein Foto des Heizelements. Wir identifizieren das kompatible Element innerhalb von 24 Std.<br \/>\n<strong>\u2192 Kontaktieren Sie unser Vertriebsteam: <a href=\"mailto:contact@refsas.fr\">contact@refsas.fr<\/a> | <a href=\"tel:+330147211317\">01 47 21 13 17<\/a><\/strong>[\/vc_column_text][\/vc_column][\/vc_row][vc_row][vc_column width=&#8220;1\/1&#8243;][vc_column_text uncode_shortcode_id=&#8220;209139&#8243;]<\/p>\n<h2>Technische Eigenschaften von MoSi\u2082-Heizelementen f\u00fcr Dental\u00f6fen<\/h2>\n<p>MoSi\u2082-Heizelemente sind in <strong>5 Standardgr\u00f6\u00dfen<\/strong> erh\u00e4ltlich, die durch ihren Durchmesser in der Heizzone \/ am kalten Ende (mm) gekennzeichnet sind. Jede Gr\u00f6\u00dfe entspricht unterschiedlichen Ofenkonfigurationen, wobei die empfohlenen maximalen Stromst\u00e4rken unbedingt einzuhalten sind, um die Lebensdauer des Elements zu gew\u00e4hrleisten. <\/p>\n<h3>Abmessungen und elektrische Eigenschaften<\/h3>\n<p>Der Durchmesser <strong>Le\/Lu<\/strong> bezeichnet das Verh\u00e4ltnis zwischen dem Durchmesser der Heizzone (Le) und dem der kalten Enden (Lu). Der Achsabstand (a) ist der Abstand zwischen den beiden Schenkeln des U-f\u00f6rmigen Elements. <strong>Die empfohlene maximale Stromst\u00e4rke ist eine absolute Grenze<\/strong>: Ein \u00dcberschreiten f\u00fchrt zu einer beschleunigten Verschlechterung oder sogar zum sofortigen Bruch.[\/vc_column_text][vc_row_inner row_inner_height_percent=&#8220;0&#8243; overlay_alpha=&#8220;50&#8243; gutter_size=&#8220;3&#8243; shift_y=&#8220;0&#8243; z_index=&#8220;0&#8243; uncode_shortcode_id=&#8220;140398&#8243;][vc_column_inner column_width_percent=&#8220;100&#8243; align_horizontal=&#8220;align_center&#8220; gutter_size=&#8220;3&#8243; overlay_alpha=&#8220;50&#8243; shift_x=&#8220;0&#8243; shift_y=&#8220;0&#8243; shift_y_down=&#8220;0&#8243; z_index=&#8220;0&#8243; medium_width=&#8220;0&#8243; mobile_width=&#8220;0&#8243; width=&#8220;1\/1&#8243; uncode_shortcode_id=&#8220;211577&#8243;][vc_single_image media=&#8220;75590&#8243; media_lightbox=&#8220;yes&#8220; media_width_percent=&#8220;20&#8243; alignment=&#8220;center&#8220; uncode_shortcode_id=&#8220;198510&#8243;][\/vc_column_inner][\/vc_row_inner][vc_row_inner][vc_column_inner width=&#8220;1\/1&#8243;][\/vc_column_inner][\/vc_row_inner][\/vc_column][\/vc_row][vc_row row_height_percent=&#8220;0&#8243; overlay_alpha=&#8220;49&#8243; gutter_size=&#8220;3&#8243; column_width_percent=&#8220;100&#8243; shift_y=&#8220;0&#8243; z_index=&#8220;0&#8243; content_parallax=&#8220;0&#8243; uncode_shortcode_id=&#8220;802065&#8243;][vc_column column_width_percent=&#8220;100&#8243; gutter_size=&#8220;3&#8243; override_padding=&#8220;yes&#8220; column_padding=&#8220;3&#8243; overlay_color=&#8220;color-dfgh&#8220; overlay_alpha=&#8220;5&#8243; border_color=&#8220;color-dfgh&#8220; border_style=&#8220;solid&#8220; shift_x=&#8220;0&#8243; shift_y=&#8220;0&#8243; shift_y_down=&#8220;0&#8243; z_index=&#8220;0&#8243; medium_width=&#8220;0&#8243; mobile_width=&#8220;0&#8243; width=&#8220;1\/1&#8243; uncode_shortcode_id=&#8220;850585&#8243; overlay_color_type=&#8220;uncode-palette&#8220; css=&#8220;.vc_custom_1774622512779{border-left-width: 4px !important;}&#8220; border_color_type=&#8220;uncode-palette&#8220;][vc_column_text text_color=&#8220;color-wayh&#8220; uncode_shortcode_id=&#8220;499480&#8243; text_color_type=&#8220;uncode-palette&#8220;]<\/p>\n<h2>Wie w\u00e4hlt man die richtige Gr\u00f6\u00dfe f\u00fcr einen Dentalofen aus?<\/h2>\n<p>F\u00fcr einen Standard-Dentallaborofen (Zirkonoxid-Sintern oder Keramikbrennen) decken die Gr\u00f6\u00dfen 3\/6 und 4\/9 die gro\u00dfe Mehrheit der Anwendungen ab. Die Gr\u00f6\u00dfe 6\/12 wird in Hochleistungs-Sinter\u00f6fen oder bei intensiven Zyklen verwendet. Im Zweifelsfall identifiziert SAS FOURS die Originalgr\u00f6\u00dfe anhand des Ofenmodells.[\/vc_column_text][\/vc_column][\/vc_row][vc_row][vc_column width=&#8220;1\/1&#8243;][vc_column_text uncode_shortcode_id=&#8220;175747&#8243;]<\/p>\n<h3>Maximale Oberfl\u00e4chentemperatur je nach Ofenatmosph\u00e4re<\/h3>\n<p>Die maximale Einsatztemperatur eines MoSi\u2082-Heizelements <strong>variiert erheblich je nach Atmosph\u00e4re<\/strong> im Ofenraum. Dieser Punkt wird oft ignoriert, bestimmt jedoch direkt die Lebensdauer des Elements. Dental\u00f6fen arbeiten in der Regel unter Luft oder leichter kontrollierter Atmosph\u00e4re \u2013 die Werte in den Spalten 1.600 \u00b0C und 1.800 \u00b0C geben die einzuhaltenden Grenzwerte an.[\/vc_column_text][vc_row_inner][vc_column_inner width=&#8220;1\/1&#8243;][\/vc_column_inner][\/vc_row_inner][vc_column_text uncode_shortcode_id=&#8220;372058&#8243;]<\/p>\n<h2>Wie ersetzt man das Heizelement eines Dentalofens?<\/h2>\n<p>Der Austausch eines MoSi\u2082- oder SiC-Heizelements ist kein trivialer Vorgang. Diese Elemente sind mechanisch zerbrechlich, empfindlich gegen\u00fcber thermischen Spannungen und m\u00fcssen mit dem passenden Zubeh\u00f6r montiert werden, um eine lange Haltbarkeit zu gew\u00e4hrleisten. <\/p>\n<ol>\n<li style=\"list-style-type: none;\">\n<ol>\n<li><strong>Genaue Referenz identifizieren<\/strong>: Ofenmarke, Modell, Seriennummer. Falls nicht vorhanden, Abmessungen des Elements (Durchmesser, L\u00e4nge, Form). <\/li>\n<li><strong>Elektrische Konfiguration pr\u00fcfen<\/strong>: gegen\u00fcberliegende, nebeneinanderliegende oder 90\u00b0-Anschl\u00fcsse, Kaltwiderstand des Elements in Ohm.<\/li>\n<li><strong>Montagezubeh\u00f6r bestellen<\/strong>: Wandisolierteile, Aluminium-Anschlusslitzen, Spannschellen aus hitzebest\u00e4ndigem Stahl.<\/li>\n<li><strong>Schrittweise Temperaturerh\u00f6hung durchf\u00fchren<\/strong>: Ein neues Element darf niemals abrupt der Maximaltemperatur ausgesetzt werden. Ein schrittweiser Vorw\u00e4rmzyklus ist unerl\u00e4sslich. <\/li>\n<li><strong>Elektrische Anschl\u00fcsse pr\u00fcfen<\/strong>: Eine schlechte Verbindung ist die Hauptursache f\u00fcr den vorzeitigen Bruch von MoSi\u2082-Heizelementen.<\/li>\n<\/ol>\n<\/li>\n<\/ol>\n<p>SAS FOURS verf\u00fcgt \u00fcber qualifizierte Techniker f\u00fcr die Montage, falls Sie diesen Vorgang nicht selbst durchf\u00fchren m\u00f6chten.[\/vc_column_text][\/vc_column][\/vc_row][vc_row row_height_percent=&#8220;0&#8243; back_color=&#8220;color-iopl&#8220; overlay_alpha=&#8220;50&#8243; gutter_size=&#8220;3&#8243; column_width_percent=&#8220;100&#8243; shift_y=&#8220;0&#8243; z_index=&#8220;0&#8243; content_parallax=&#8220;0&#8243; uncode_shortcode_id=&#8220;664662&#8243; back_color_type=&#8220;uncode-palette&#8220;][vc_column column_width_percent=&#8220;100&#8243; gutter_size=&#8220;4&#8243; style=&#8220;dark&#8220; overlay_alpha=&#8220;50&#8243; shift_x=&#8220;0&#8243; shift_y=&#8220;0&#8243; shift_y_down=&#8220;0&#8243; z_index=&#8220;0&#8243; medium_width=&#8220;0&#8243; mobile_width=&#8220;0&#8243; width=&#8220;1\/1&#8243; uncode_shortcode_id=&#8220;740771&#8243;][vc_row_inner][vc_column_inner column_width_percent=&#8220;100&#8243; align_horizontal=&#8220;align_center&#8220; gutter_size=&#8220;3&#8243; style=&#8220;dark&#8220; overlay_alpha=&#8220;50&#8243; shift_x=&#8220;0&#8243; shift_y=&#8220;0&#8243; shift_y_down=&#8220;0&#8243; z_index=&#8220;0&#8243; medium_width=&#8220;0&#8243; mobile_width=&#8220;0&#8243; width=&#8220;1\/1&#8243; uncode_shortcode_id=&#8220;179499&#8243;][vc_custom_heading uncode_shortcode_id=&#8220;118202&#8243;]Warum sollten Sie SAS FOURS f\u00fcr Ihre Dental-Heizelemente w\u00e4hlen?[\/vc_custom_heading][\/vc_column_inner][\/vc_row_inner][vc_row_inner row_inner_height_percent=&#8220;0&#8243; overlay_alpha=&#8220;100&#8243; gutter_size=&#8220;4&#8243; shift_y=&#8220;0&#8243; z_index=&#8220;0&#8243; uncode_shortcode_id=&#8220;202388&#8243;][vc_column_inner column_width_percent=&#8220;100&#8243; align_horizontal=&#8220;align_center&#8220; gutter_size=&#8220;3&#8243; style=&#8220;dark&#8220; overlay_alpha=&#8220;100&#8243; shift_x=&#8220;0&#8243; shift_y=&#8220;0&#8243; shift_y_down=&#8220;0&#8243; z_index=&#8220;0&#8243; medium_width=&#8220;3&#8243; mobile_width=&#8220;0&#8243; zoom_width=&#8220;0&#8243; zoom_height=&#8220;0&#8243; width=&#8220;1\/4&#8243; uncode_shortcode_id=&#8220;169367&#8243;][vc_icon icon=&#8220;fa fa-star&#8220; icon_color=&#8220;color-xsdn&#8220; size=&#8220;fa-3x&#8220; heading_semantic=&#8220;p&#8220; text_size=&#8220;h5&#8243; text_weight=&#8220;400&#8243; text_reduced=&#8220;yes&#8220; align=&#8220;left&#8220; title=&#8220;85 Jahre&#8220; uncode_shortcode_id=&#8220;341050&#8243; icon_color_type=&#8220;uncode-palette&#8220;]Erfahrung[\/vc_icon][\/vc_column_inner][vc_column_inner column_width_percent=&#8220;100&#8243; align_horizontal=&#8220;align_center&#8220; gutter_size=&#8220;3&#8243; style=&#8220;dark&#8220; overlay_alpha=&#8220;100&#8243; shift_x=&#8220;0&#8243; shift_y=&#8220;0&#8243; shift_y_down=&#8220;0&#8243; z_index=&#8220;0&#8243; medium_width=&#8220;3&#8243; mobile_width=&#8220;0&#8243; zoom_width=&#8220;0&#8243; zoom_height=&#8220;0&#8243; width=&#8220;1\/4&#8243; uncode_shortcode_id=&#8220;100587&#8243;][vc_icon icon=&#8220;fa fa-certificate&#8220; icon_color=&#8220;color-xsdn&#8220; size=&#8220;fa-3x&#8220; heading_semantic=&#8220;p&#8220; text_size=&#8220;h5&#8243; text_weight=&#8220;400&#8243; text_reduced=&#8220;yes&#8220; align=&#8220;left&#8220; title=&#8220;Zertifiziert&#8220; uncode_shortcode_id=&#8220;212251&#8243; icon_color_type=&#8220;uncode-palette&#8220;]ISO 9001[\/vc_icon][\/vc_column_inner][vc_column_inner column_width_percent=&#8220;100&#8243; align_horizontal=&#8220;align_center&#8220; gutter_size=&#8220;3&#8243; style=&#8220;dark&#8220; overlay_alpha=&#8220;100&#8243; shift_x=&#8220;0&#8243; shift_y=&#8220;0&#8243; shift_y_down=&#8220;0&#8243; z_index=&#8220;0&#8243; medium_width=&#8220;3&#8243; mobile_width=&#8220;0&#8243; zoom_width=&#8220;0&#8243; zoom_height=&#8220;0&#8243; width=&#8220;1\/4&#8243; uncode_shortcode_id=&#8220;990981&#8243;][vc_icon icon=&#8220;fa fa-group&#8220; icon_color=&#8220;color-xsdn&#8220; size=&#8220;fa-3x&#8220; heading_semantic=&#8220;p&#8220; text_size=&#8220;h5&#8243; text_weight=&#8220;400&#8243; text_reduced=&#8220;yes&#8220; align=&#8220;left&#8220; title=&#8220;400+&#8220; uncode_shortcode_id=&#8220;213288&#8243; icon_color_type=&#8220;uncode-palette&#8220;]Industriekunden[\/vc_icon][\/vc_column_inner][vc_column_inner column_width_percent=&#8220;100&#8243; align_horizontal=&#8220;align_center&#8220; gutter_size=&#8220;3&#8243; style=&#8220;dark&#8220; overlay_alpha=&#8220;50&#8243; shift_x=&#8220;0&#8243; shift_y=&#8220;0&#8243; shift_y_down=&#8220;0&#8243; z_index=&#8220;0&#8243; medium_visibility=&#8220;yes&#8220; medium_width=&#8220;3&#8243; mobile_width=&#8220;0&#8243; width=&#8220;1\/4&#8243; uncode_shortcode_id=&#8220;537493&#8243;][vc_icon icon=&#8220;fa fa-comments&#8220; icon_color=&#8220;color-xsdn&#8220; size=&#8220;fa-3x&#8220; heading_semantic=&#8220;p&#8220; text_size=&#8220;h5&#8243; text_weight=&#8220;400&#8243; text_reduced=&#8220;yes&#8220; align=&#8220;left&#8220; title=&#8220;24 Stunden&#8220; uncode_shortcode_id=&#8220;117980&#8243; icon_color_type=&#8220;uncode-palette&#8220;]Antwortzeit[\/vc_icon][\/vc_column_inner][\/vc_row_inner][vc_column_text text_lead=&#8220;yes&#8220; uncode_shortcode_id=&#8220;370119&#8243;]<\/p>\n<ul>\n<li>Sie kaufen direkt bei einem franz\u00f6sischen Industrieunternehmen, das seit 85 Jahren auf \u00d6fen, Feuerfestmaterialien und Heizelemente spezialisiert ist.<\/li>\n<li>Internes Konstruktionsb\u00fcro zur Identifizierung des kompatiblen Elements auch ohne pr\u00e4zise Referenz<\/li>\n<li>Lieferung des Montagezubeh\u00f6rs (Keramikteile, Litzen, Halterungen) zusammen mit dem Heizelement.<\/li>\n<li>Verf\u00fcgbare Techniker f\u00fcr die Installation bei Bedarf<\/li>\n<li>ISO 9001 Zertifizierung (vollst\u00e4ndige R\u00fcckverfolgbarkeit der Produkte)<\/li>\n<\/ul>\n<p>[\/vc_column_text][\/vc_column][\/vc_row][vc_row row_height_percent=&#8220;0&#8243; override_padding=&#8220;yes&#8220; h_padding=&#8220;2&#8243; top_padding=&#8220;2&#8243; bottom_padding=&#8220;2&#8243; overlay_alpha=&#8220;50&#8243; gutter_size=&#8220;4&#8243; column_width_percent=&#8220;100&#8243; shift_y=&#8220;0&#8243; z_index=&#8220;0&#8243; top_divider=&#8220;gradient&#8220; content_parallax=&#8220;0&#8243; uncode_shortcode_id=&#8220;546174&#8243;][vc_column column_width_percent=&#8220;100&#8243; gutter_size=&#8220;2&#8243; overlay_alpha=&#8220;50&#8243; shift_x=&#8220;0&#8243; shift_y=&#8220;0&#8243; shift_y_down=&#8220;0&#8243; z_index=&#8220;0&#8243; medium_width=&#8220;0&#8243; mobile_width=&#8220;0&#8243; css_animation=&#8220;alpha-anim&#8220; animation_speed=&#8220;1000&#8243; width=&#8220;1\/1&#8243; uncode_shortcode_id=&#8220;115894&#8243;][vc_row_inner][vc_column_inner column_width_percent=&#8220;100&#8243; gutter_size=&#8220;3&#8243; overlay_alpha=&#8220;50&#8243; shift_x=&#8220;0&#8243; shift_y=&#8220;0&#8243; shift_y_down=&#8220;0&#8243; z_index=&#8220;0&#8243; medium_width=&#8220;0&#8243; mobile_width=&#8220;0&#8243; width=&#8220;1\/1&#8243; uncode_shortcode_id=&#8220;530811&#8243;][vc_custom_heading uncode_shortcode_id=&#8220;646698&#8243;]H\u00e4ufig gestellte Fragen \u2014 Dentalofen-Heizelement[\/vc_custom_heading][\/vc_column_inner][\/vc_row_inner][vc_accordion typography=&#8220;advanced&#8220; sign=&#8220;plus&#8220; gutter_simple=&#8220;1&#8243; no_h_padding=&#8220;yes&#8220; titles_size=&#8220;h4&#8243; titles_weight=&#8220;500&#8243; uncode_shortcode_id=&#8220;118970&#8243; active_tab=&#8220;0&#8243;][vc_accordion_tab gutter_size=&#8220;2&#8243; column_padding=&#8220;2&#8243; title=&#8220;Wie hoch ist die Lebensdauer eines MoSi\u2082-Heizelements in einem Dentalofen?&#8220; tab_id=&#8220;1665420124-1-861666889187905171561023870500c9-4128&#8243;][vc_column_text uncode_shortcode_id=&#8220;172994&#8243;]Die Lebensdauer h\u00e4ngt direkt vom Profil der thermischen Zyklen ab. Bei normalem Gebrauch im Dentallabor (mehrere Zyklen pro Tag) h\u00e4lt ein hochwertiges MoSi\u2082-Heizelement typischerweise zwischen 2 und 5 Jahren. Vorzeitige Br\u00fcche sind fast immer auf eine fehlerhafte Montage, eine schlecht angezogene Verbindung oder eine zu abrupte Temperaturerh\u00f6hung zur\u00fcckzuf\u00fchren.[\/vc_column_text][\/vc_accordion_tab][vc_accordion_tab gutter_size=&#8220;2&#8243; column_padding=&#8220;2&#8243; title=&#8220;Wie erkennt man, ob das Heizelement oder das Thermoelement defekt ist?&#8220; tab_id=&#8220;1665420124-2-01666889187905171561023870500c9-4128&#8243;][vc_column_text uncode_shortcode_id=&#8220;202026&#8243;]Ein defektes Heizelement verursacht in der Regel eine Fehlermeldung wie \u201e\u00dcberhitzung\u201c, \u201eFehler Heizelement\u201c oder eine unm\u00f6gliche Temperaturerh\u00f6hung. Ein defektes Thermoelement liefert fehlerhafte Temperaturwerte (inkonsistente Werte, F\u00fchlerfehler). Beide Defekte k\u00f6nnen gleichzeitig auftreten. Eine Messung des elektrischen Kaltwiderstands am Heizelement erm\u00f6glicht es, einen Defekt des Heizelements zu best\u00e4tigen oder auszuschlie\u00dfen.[\/vc_column_text][\/vc_accordion_tab][vc_accordion_tab gutter_size=&#8220;2&#8243; column_padding=&#8220;2&#8243; title=&#8220;Kann man ein MoSi\u2082-Heizelement durch ein SiC-Heizelement ersetzen?&#8220; tab_id=&#8220;efe01523-2776-61666889187905171561023870500c9-4128&#8243;][vc_column_text uncode_shortcode_id=&#8220;208885&#8243;]Nein, nicht direkt. Diese beiden Technologien haben unterschiedliche elektrische und mechanische Eigenschaften. Das Ersatzheizelement muss vom gleichen Typ wie das Original sein oder ein vom Ofenhersteller validierter Ersatz. SAS FOURS kann Ihnen helfen, die Kompatibilit\u00e4t zu pr\u00fcfen.[\/vc_column_text][\/vc_accordion_tab][vc_accordion_tab gutter_size=&#8220;2&#8243; column_padding=&#8220;2&#8243; title=&#8220;Wie sind die Lieferbedingungen?&#8220; tab_id=&#8220;10314d48-70e0-01666889187905171561023870500c9-4128&#8243;][vc_column_text uncode_shortcode_id=&#8220;928394&#8243;]Wir liefern nach Frankreich und Europa, auch bei Bestellungen in kleinen Mengen. Kontaktieren Sie unser Vertriebsteam f\u00fcr ein Angebot.[\/vc_column_text][\/vc_accordion_tab][vc_accordion_tab gutter_size=&#8220;2&#8243; column_padding=&#8220;2&#8243; title=&#8220;Wie viel kostet ein MoSi\u2082-Heizelement f\u00fcr einen Dentalofen?&#8220; tab_id=&#8220;6232a039-f9b5-71666889187905171561023870500c9-4128&#8243;][vc_column_text uncode_shortcode_id=&#8220;961419&#8243;]Der Preis h\u00e4ngt vom Modell ab (Gr\u00f6\u00dfe, Form, Qualit\u00e4t 1.600 \u00b0C oder 1.800 \u00b0C). Standardelemente f\u00fcr Dental\u00f6fen sind erschwinglich. Kontaktieren Sie uns mit der Referenz Ihres Ofens, um innerhalb von 24 Std. einen pr\u00e4zisen Preis zu erhalten.[\/vc_column_text][\/vc_accordion_tab][vc_accordion_tab gutter_size=&#8220;2&#8243; column_padding=&#8220;2&#8243; title=&#8220;Mein Dentalofen hat keine Garantie mehr. Kann ich ihn selbst reparieren? &#8220; tab_id=&#8220;1774624337216-5-4&#8243;][vc_column_text uncode_shortcode_id=&#8220;199301&#8243;]Der Austausch eines MoSi\u2082-Heizelements erfordert spezifische technische Vorsichtsma\u00dfnahmen (mechanische Zerbrechlichkeit, Aufheizzyklus). Wenn Sie \u00fcber die entsprechenden Kompetenzen verf\u00fcgen, liefert Ihnen SAS FOURS das Element und das Zubeh\u00f6r zusammen mit den Montageempfehlungen. Andernfalls k\u00f6nnen wir den Einsatz f\u00fcr Sie \u00fcbernehmen.[\/vc_column_text][\/vc_accordion_tab][\/vc_accordion][\/vc_column][\/vc_row][vc_row row_height_percent=&#8220;50&#8243; override_padding=&#8220;yes&#8220; h_padding=&#8220;2&#8243; top_padding=&#8220;4&#8243; bottom_padding=&#8220;3&#8243; back_color=&#8220;color-lxmt&#8220; overlay_alpha=&#8220;50&#8243; gutter_size=&#8220;3&#8243; column_width_percent=&#8220;100&#8243; shift_y=&#8220;0&#8243; z_index=&#8220;0&#8243; content_parallax=&#8220;0&#8243; uncode_shortcode_id=&#8220;457699&#8243; back_color_type=&#8220;uncode-palette&#8220;][vc_column column_width_use_pixel=&#8220;yes&#8220; position_vertical=&#8220;middle&#8220; align_horizontal=&#8220;align_center&#8220; gutter_size=&#8220;2&#8243; overlay_alpha=&#8220;50&#8243; shift_x=&#8220;0&#8243; shift_y=&#8220;0&#8243; shift_y_down=&#8220;0&#8243; z_index=&#8220;0&#8243; medium_width=&#8220;0&#8243; mobile_width=&#8220;0&#8243; width=&#8220;1\/1&#8243; column_width_pixel=&#8220;900&#8243; uncode_shortcode_id=&#8220;871736&#8243;][vc_custom_heading text_color=&#8220;color-iopl&#8220; text_size=&#8220;h6&#8243; text_transform=&#8220;capitalize&#8220; uncode_shortcode_id=&#8220;209761&#8243; text_color_type=&#8220;uncode-palette&#8220;]Ofen defekt?[\/vc_custom_heading][vc_custom_heading heading_semantic=&#8220;h3&#8243; text_weight=&#8220;400&#8243; sub_reduced=&#8220;yes&#8220; uncode_shortcode_id=&#8220;199176&#8243;]Dentalofen-Heizelement \u2014 Schnelles Angebot innerhalb von 24 Std.[\/vc_custom_heading][vc_column_text text_lead=&#8220;yes&#8220; uncode_shortcode_id=&#8220;121942&#8243;]Senden Sie uns die Marke und das Modell Ihres Ofens. Auch ohne genaue Referenznummer.<br \/>\n<strong>Schnelles Angebot innerhalb von 24 Std. \u2013 Lieferung nach Frankreich &#038; Europa.<\/strong>[\/vc_column_text][vc_empty_space empty_h=&#8220;2&#8243;][vc_button button_color=&#8220;accent&#8220; radius=&#8220;btn-circle&#8220; outline=&#8220;yes&#8220; border_width=&#8220;0&#8243; display=&#8220;inline&#8220; link=&#8220;url:https%3A%2F%2Fwww.refsas.com%2Fde%2Fkontakt%2F|title:Kontakt|&#8220; button_color_type=&#8220;uncode-palette&#8220; uncode_shortcode_id=&#8220;193932&#8243;]Kontaktieren Sie unser Expertenteam[\/vc_button][vc_button button_color=&#8220;accent&#8220; radius=&#8220;btn-circle&#8220; border_width=&#8220;0&#8243; display=&#8220;inline&#8220; link=&#8220;url:tel%3A%2B33147211317|&#8220; button_color_type=&#8220;uncode-palette&#8220; uncode_shortcode_id=&#8220;148001&#8243;]01 47 21 13 17[\/vc_button][\/vc_column][\/vc_row][vc_row row_height_percent=&#8220;0&#8243; override_padding=&#8220;yes&#8220; h_padding=&#8220;2&#8243; top_padding=&#8220;0&#8243; bottom_padding=&#8220;1&#8243; overlay_alpha=&#8220;50&#8243; gutter_size=&#8220;3&#8243; column_width_percent=&#8220;100&#8243; shift_y=&#8220;0&#8243; z_index=&#8220;0&#8243; content_parallax=&#8220;0&#8243; uncode_shortcode_id=&#8220;147122&#8243;][vc_column column_width_percent=&#8220;100&#8243; gutter_size=&#8220;3&#8243; overlay_alpha=&#8220;50&#8243; shift_x=&#8220;0&#8243; shift_y=&#8220;0&#8243; shift_y_down=&#8220;0&#8243; z_index=&#8220;0&#8243; medium_width=&#8220;0&#8243; mobile_width=&#8220;0&#8243; width=&#8220;1\/1&#8243; uncode_shortcode_id=&#8220;102239&#8243;][vc_column_text text_lead=&#8220;small&#8220; uncode_shortcode_id=&#8220;473705&#8243;]<em>Die genannten Marken dienen lediglich der Orientierung zur leichteren Identifizierung der Ger\u00e4te. SAS FOURS ist nicht mit den genannten Herstellern verbunden. <\/em>[\/vc_column_text][\/vc_column][\/vc_row]<\/p>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>[vc_row row_height_percent=&#8220;50&#8243; back_color=&#8220;color-wayh&#8220; back_image=&#8220;74962&#8243; overlay_color=&#8220;color-wayh&#8220; overlay_alpha=&#8220;50&#8243; gutter_size=&#8220;3&#8243; column_width_percent=&#8220;100&#8243; shift_y=&#8220;0&#8243; z_index=&#8220;0&#8243; content_parallax=&#8220;0&#8243; uncode_shortcode_id=&#8220;561251&#8243; back_color_type=&#8220;uncode-palette&#8220; overlay_color_type=&#8220;uncode-palette&#8220;][vc_column column_width_percent=&#8220;100&#8243; gutter_size=&#8220;3&#8243; overlay_alpha=&#8220;50&#8243; shift_x=&#8220;0&#8243; shift_y=&#8220;0&#8243; shift_y_down=&#8220;0&#8243; [&hellip;]<\/p>\n","protected":false},"author":2,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"footnotes":""},"class_list":["post-75589","page","type-page","status-publish","hentry"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.8 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Heizelemente f\u00fcr Dental\u00f6fen: MoSi2 &amp; SiC \u2013 Expertise von REFSAS<\/title>\n<meta name=\"description\" content=\"Heizelement Ihres Dentalofens defekt? Angebot innerhalb von 24 Std., Beratung zur Kompatibilit\u00e4t f\u00fcr alle Marken. MoSi2- und SiC-Heizelemente f\u00fcr Dental\u00f6fen.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.refsas.com\/de\/heizelement-ihres-dentalofens-defekt-finden-sie-schnell-den-passenden-ersatz\/\" \/>\n<meta property=\"og:locale\" content=\"de_DE\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Heizelemente f\u00fcr Dental\u00f6fen: MoSi2 &amp; SiC \u2013 Expertise von REFSAS\" \/>\n<meta property=\"og:description\" content=\"Heizelement Ihres Dentalofens defekt? Angebot innerhalb von 24 Std., Beratung zur Kompatibilit\u00e4t f\u00fcr alle Marken. MoSi2- und SiC-Heizelemente f\u00fcr Dental\u00f6fen.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.refsas.com\/de\/heizelement-ihres-dentalofens-defekt-finden-sie-schnell-den-passenden-ersatz\/\" \/>\n<meta property=\"og:site_name\" content=\"SAS Fours et r\u00e9fractaires\" \/>\n<meta property=\"article:modified_time\" content=\"2026-06-18T10:04:52+00:00\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Gesch\u00e4tzte Lesezeit\" \/>\n\t<meta name=\"twitter:data1\" content=\"18\u00a0Minuten\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.refsas.com\\\/de\\\/heizelement-ihres-dentalofens-defekt-finden-sie-schnell-den-passenden-ersatz\\\/\",\"url\":\"https:\\\/\\\/www.refsas.com\\\/de\\\/heizelement-ihres-dentalofens-defekt-finden-sie-schnell-den-passenden-ersatz\\\/\",\"name\":\"Heizelemente f\u00fcr Dental\u00f6fen: MoSi2 & SiC \u2013 Expertise von REFSAS\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.refsas.com\\\/#website\"},\"datePublished\":\"2026-06-18T08:31:59+00:00\",\"dateModified\":\"2026-06-18T10:04:52+00:00\",\"description\":\"Heizelement Ihres Dentalofens defekt? Angebot innerhalb von 24 Std., Beratung zur Kompatibilit\u00e4t f\u00fcr alle Marken. MoSi2- und SiC-Heizelemente f\u00fcr Dental\u00f6fen.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.refsas.com\\\/de\\\/heizelement-ihres-dentalofens-defekt-finden-sie-schnell-den-passenden-ersatz\\\/#breadcrumb\"},\"inLanguage\":\"de\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.refsas.com\\\/de\\\/heizelement-ihres-dentalofens-defekt-finden-sie-schnell-den-passenden-ersatz\\\/\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.refsas.com\\\/de\\\/heizelement-ihres-dentalofens-defekt-finden-sie-schnell-den-passenden-ersatz\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Accueil\",\"item\":\"https:\\\/\\\/www.refsas.com\\\/de\\\/sas-four-spezialist-fur-industrieofen-und-feuerfestmaterialien-seit-1934\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Heizelement Ihres Dentalofens defekt? Finden Sie schnell den passenden Ersatz.\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/www.refsas.com\\\/#website\",\"url\":\"https:\\\/\\\/www.refsas.com\\\/\",\"name\":\"SAS Fours et r\u00e9fractaires\",\"description\":\"Architectes du chaud sur mesure\",\"publisher\":{\"@id\":\"https:\\\/\\\/www.refsas.com\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/www.refsas.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"de\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/www.refsas.com\\\/#organization\",\"name\":\"REFSAS Fours et R\u00e9fractaires\",\"url\":\"https:\\\/\\\/www.refsas.com\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"de\",\"@id\":\"https:\\\/\\\/www.refsas.com\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/www.refsas.com\\\/wp-content\\\/uploads\\\/2019\\\/02\\\/logo.png\",\"contentUrl\":\"https:\\\/\\\/www.refsas.com\\\/wp-content\\\/uploads\\\/2019\\\/02\\\/logo.png\",\"width\":230,\"height\":150,\"caption\":\"REFSAS Fours et R\u00e9fractaires\"},\"image\":{\"@id\":\"https:\\\/\\\/www.refsas.com\\\/#\\\/schema\\\/logo\\\/image\\\/\"}}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Heizelemente f\u00fcr Dental\u00f6fen: MoSi2 & SiC \u2013 Expertise von REFSAS","description":"Heizelement Ihres Dentalofens defekt? Angebot innerhalb von 24 Std., Beratung zur Kompatibilit\u00e4t f\u00fcr alle Marken. MoSi2- und SiC-Heizelemente f\u00fcr Dental\u00f6fen.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.refsas.com\/de\/heizelement-ihres-dentalofens-defekt-finden-sie-schnell-den-passenden-ersatz\/","og_locale":"de_DE","og_type":"article","og_title":"Heizelemente f\u00fcr Dental\u00f6fen: MoSi2 & SiC \u2013 Expertise von REFSAS","og_description":"Heizelement Ihres Dentalofens defekt? Angebot innerhalb von 24 Std., Beratung zur Kompatibilit\u00e4t f\u00fcr alle Marken. MoSi2- und SiC-Heizelemente f\u00fcr Dental\u00f6fen.","og_url":"https:\/\/www.refsas.com\/de\/heizelement-ihres-dentalofens-defekt-finden-sie-schnell-den-passenden-ersatz\/","og_site_name":"SAS Fours et r\u00e9fractaires","article_modified_time":"2026-06-18T10:04:52+00:00","twitter_card":"summary_large_image","twitter_misc":{"Gesch\u00e4tzte Lesezeit":"18\u00a0Minuten"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/www.refsas.com\/de\/heizelement-ihres-dentalofens-defekt-finden-sie-schnell-den-passenden-ersatz\/","url":"https:\/\/www.refsas.com\/de\/heizelement-ihres-dentalofens-defekt-finden-sie-schnell-den-passenden-ersatz\/","name":"Heizelemente f\u00fcr Dental\u00f6fen: MoSi2 & SiC \u2013 Expertise von REFSAS","isPartOf":{"@id":"https:\/\/www.refsas.com\/#website"},"datePublished":"2026-06-18T08:31:59+00:00","dateModified":"2026-06-18T10:04:52+00:00","description":"Heizelement Ihres Dentalofens defekt? Angebot innerhalb von 24 Std., Beratung zur Kompatibilit\u00e4t f\u00fcr alle Marken. MoSi2- und SiC-Heizelemente f\u00fcr Dental\u00f6fen.","breadcrumb":{"@id":"https:\/\/www.refsas.com\/de\/heizelement-ihres-dentalofens-defekt-finden-sie-schnell-den-passenden-ersatz\/#breadcrumb"},"inLanguage":"de","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.refsas.com\/de\/heizelement-ihres-dentalofens-defekt-finden-sie-schnell-den-passenden-ersatz\/"]}]},{"@type":"BreadcrumbList","@id":"https:\/\/www.refsas.com\/de\/heizelement-ihres-dentalofens-defekt-finden-sie-schnell-den-passenden-ersatz\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Accueil","item":"https:\/\/www.refsas.com\/de\/sas-four-spezialist-fur-industrieofen-und-feuerfestmaterialien-seit-1934\/"},{"@type":"ListItem","position":2,"name":"Heizelement Ihres Dentalofens defekt? Finden Sie schnell den passenden Ersatz."}]},{"@type":"WebSite","@id":"https:\/\/www.refsas.com\/#website","url":"https:\/\/www.refsas.com\/","name":"SAS Fours et r\u00e9fractaires","description":"Architectes du chaud sur mesure","publisher":{"@id":"https:\/\/www.refsas.com\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.refsas.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"de"},{"@type":"Organization","@id":"https:\/\/www.refsas.com\/#organization","name":"REFSAS Fours et R\u00e9fractaires","url":"https:\/\/www.refsas.com\/","logo":{"@type":"ImageObject","inLanguage":"de","@id":"https:\/\/www.refsas.com\/#\/schema\/logo\/image\/","url":"https:\/\/www.refsas.com\/wp-content\/uploads\/2019\/02\/logo.png","contentUrl":"https:\/\/www.refsas.com\/wp-content\/uploads\/2019\/02\/logo.png","width":230,"height":150,"caption":"REFSAS Fours et R\u00e9fractaires"},"image":{"@id":"https:\/\/www.refsas.com\/#\/schema\/logo\/image\/"}}]}},"_links":{"self":[{"href":"https:\/\/www.refsas.com\/de\/wp-json\/wp\/v2\/pages\/75589","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.refsas.com\/de\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.refsas.com\/de\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.refsas.com\/de\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/www.refsas.com\/de\/wp-json\/wp\/v2\/comments?post=75589"}],"version-history":[{"count":7,"href":"https:\/\/www.refsas.com\/de\/wp-json\/wp\/v2\/pages\/75589\/revisions"}],"predecessor-version":[{"id":75820,"href":"https:\/\/www.refsas.com\/de\/wp-json\/wp\/v2\/pages\/75589\/revisions\/75820"}],"wp:attachment":[{"href":"https:\/\/www.refsas.com\/de\/wp-json\/wp\/v2\/media?parent=75589"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}